Description
The MultiPaq21 data logger supports up to eight input channels for Type T or K thermocouples, enabling simultaneous temperature measurement at multiple points within the product and its surrounding environment. With flexible thermocouple cabling, sensors can be precisely placed inside the product, on the surface, or in ambient air—ensuring accurate data collection without the logger’s mass affecting sensor responsiveness or measurement reliability.
Engineered for demanding food processing conditions, the logger features a durable IP67-rated design with special waterproof connectors, offering robust protection against steam, water spray, and rigorous cleaning routines. The device can store up to eight complete thermal profiles before requiring a data download, making it ideal for high-throughput, continuous production environments.
Model Number |
DP2162A
|
DP2166A
|
DP2182A
|
DP2186A
|
---|---|---|---|---|
Thermocouple |
Type T
|
Type K
|
Type T
|
Type K
|
Channels |
6
|
6
|
8
|
8
|
Temperature measurement range |
-196ºC to 400ºC
(-320ºF to 752ºF) |
-150ºC to 1370ºC
(-238ºF to 2498ºF) |
-196ºC to 400ºC
(-320ºF to 752ºF) |
-150ºC to 1370ºC
(-238ºF to 2498ºF) |
Real-time monitoring |
Hardwired (via comms cable)
|
Hardwired (via comms cable)
RF telemetry option (TM21) |
||
Humidity option |
No
|
Yes, requires PA2020 Humidity Sensor
|
||
Accuracy |
±0.2ºC (±0.4ºF)
|
|||
Resolution |
±0.1ºC (±0.2ºF)
|
|||
Operating temperature |
-40ºC to 85ºC (-40ºF to 185ºF)
|
|||
Protection |
IP67 without thermal barrier
|
|||
Sample interval |
0.5 seconds to 50 minutes (standard use–temperature only)
2.0 seconds to 50 minutes (humidity measurement) |
|||
Memory |
1.81MB 16 hours data collection (8 thermocouples / 0.5 second sampling)
|
|||
Operation |
Rechargeable NiMH (recharge time 2.5 hours)
|
|||
Battery |
Multiple Runs (up to 8 individual repeat runs before download)
|
|||
Battery Life |
Temperature, only (0.5 second sample interval) = 120 hours
Telemetry (2.0 second sample interval) = 65 hours |